6. Inspection/Maintenance

6.3.2 Battery Replacement Procedure

(1) Remove the countersunk head screws [1] (six pieces) and detach the cover (base).

(2) Remove the batteries from the battery holder.

(3) Remove the battery connectors and connect new batteries.

After removing the old batteries, quickly connect new batteries (roughly within 5 minutes x

number of batteries).

If new batteries are not connected for a longer period, the rotation data will be lost and an

absolute reset will become necessary.

Replace batteries one axis at a time. If the batteries for all axes are replaced at once, the work

may not be completed within the specified time.

(4) Install the batteries into the battery holder.

Battery connector 1

(for axis 1)

Battery connector 2

(for axis 2)

Battery

(for axis 1)

Battery

(for axis 2)

Battery connector 4

(for axis 4)

Battery

(for axis 4)

Battery connector 3

(for axis 3)

Battery

(for axis 3)

[1] 6 - M3 x 8

Cover (base)

Battery holder