5. Precautions for Use

5.4

User Wiring and Piping

The robot comes with standard cables and tubes that the user can use in a desired wiring/piping

configuration.

User connector specifications

Rated voltage

3.0 V

Permissible current

1.1 A

Conductor size and number of wires

AWG 26 (0.15 mm

2

), 25 wires

Other

Twisted-pair cable (1 to 24), shielded

Piping specifications

Normal service pressure

0.8 MPa

4 mm x 2.5 mm, 2 pieces

Dimensions (outer diameter x inner

diameter) and number of tubes

6 mm x 4 mm, 2 pieces

Working medium

Air

ALM (indicator) specifications

Rated voltage

24 VDC

Rated current

12 mA

Illumination color

Red LED

Shape of Y-terminal

Spacer for user part installation

User Connector

D-sub 25-pin

connector for user

wiring (socket),

fixing screw M2.6

ALM (indicator)

Spacer for user

part installation

BK SW

Brake-release switch

M cable (outside robot)

PG cable (outside robot)

BK power cable (outside robot)

Y-terminal at the end

Air tube

4 (black, white)

6 (red, yellow)

M4, depth 5

30 N or less

External force applied to the spacers must not

exceed 30 N in the axial direction or 2 Nm in

the rotating direction (for each spacer).

2 Nm or less

Quick joint  6 (red)

Quick joint 4 (black)

Quick joint 6 (yellow)

Quick joint 4 (white)

5.2

3.2

2.6 5.9

7

10

U cable (outside robot)

(cable for user wiring)

Y-terminal at the end