5. Program Creating

118

X-SEL

ż: Valid

(Note 2)

z

RMDI (Move RC axis via incremental direct-value

position specification)

RC position

data mode

RC

×: Invalid

(Note 1)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration Operand 1

Operand 2

Output operation

type (output, flag)

Free

Free

RMDI

RC axis

number

Variable

number

PE

Note 1 If the command is executed, an RC position data use method error (439) will occur.

Note 2 For Fieldbus Type, (405) RC Gateway Communication Classification Error will be generated

[Function]

Perform incremental position movement using the values of variable Nos. n to n+3.

The output turns OFF when the axis movement is started, and will turn ON when the

movement is completed.

Variable number

Set item

n

Travel

n + 1

Speed [mm/s]

n + 2

Acceleration/deceleration [G]

n + 3

Positioning band [mm]

[Setting types of operation 1]

Operation 1

Specification of executing axis

0 to 15

The RC axis of the specified number moves by absolute positioning.

-1

The RC axis specified in the RAXS command moves by absolute

positioning.

* The specification of “-1” is valid only with X-SEL P/Q controllers of V0.87 or later and

X-SEL PX/QX controllers of V0.42 or later.

[Example]

LET

300

50

Set the travel as “50” mm.

LET

301

200

Set the speed as “200” mm/s.

LET

302

0.3

Set the acceleration/deceleration as “0.3” G.

LET

303

0.1

Set the positioning band as “0.1” mm.

RMDI

1

300

Move RC axis 1 via incremental position specification.