4. RC Gateway Function setting

49

[Procedure 1] Operation method setting

Select using position data in from the master (X-SEL) controller memory or slave (RC

controller) controller memories.

No.

I/O Parameter

Unit

Set Value

Default

factory setting

216 RC Gateway Function Select

-

0: To use position data in

X-SEL

1: To use position data in RC

0

[Procedure 2] Settings for Slave (Controlled Side) Axes pattern

Set the axis number for each slave.

No.

I/O Parameter

Unit

Set Value

Default

factory setting

217 RC Gateway Link Axes Pattern

(15-8)

218 RC Gateway Link Axes Pattern

(7-0)

-

00000000b to 11111111b

00000000b

Assign an axis number from 0 to 15 to each of the connected slave axes. Set the bit

corresponding to the assigned axis number to “1”. This parameter indicates the axis

number that conducts an operation.

Set “0” for those axes that are connected but will not be used.

Parameter No.217

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Axis No 15

1: Used

0: Not used

Axis No 14

1: Used

0: Not used

Axis No 13

1: Used

0: Not used

Axis No 12

1: Used

0: Not used

Axis No 11

1: Used

0: Not used

Axis No 10

1: Used

0: Not used

Axis No 9

1: Used

0: Not used

Axis No 8

1: Used

0: Not used

Parameter No.218

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Axis No 7

1: Used

0: Not used

Axis No 6

1: Used

0: Not used

Axis No 5

1: Used

0: Not used

Axis No 4

1: Used

0: Not used

Axis No 3

1: Used

0: Not used

Axis No 2

1: Used

0: Not used

Axis No 1

1: Used

0: Not used

Axis No 0

1: Used

0: Not used

(Example 1) When axis of Axis No.0 to 7 is used:

I/O Parameter No.217 = 00000000b

I/O Parameter No.218 = 11111111b

(Example 2) When axis of Axis No.0 to 11 is used:

I/O Parameter No.217 = 00001111b

I/O Parameter No.218 = 11111111b

For the setting of this parameter, refer to the list below and match the settings to those for the slave (axis to

be controlled).

Communication

System

Slave Side Controller

Remarks

PCON-SE/ACON-SE/SCON-C/ERC2-SE

Refer to 4.2.2 (1) [Procedure 1]

SIO type

ROBONET_SIO type

Refer to 4.2.2 (2) [Procedure 4]

PCON-DV/ACON-DV/SCON-CA-DV

Refer to 4.3.2 (1) [Procedure 1]

MSEP-DV

Refer to 4.3.2 (2) [Procedure 2 to 4]

Fieldbus type

MSCON-DV

Refer to 4.3.2 (3) [Procedure 2 to 4]

Advertising
This manual is related to the following products: