1 communication system – IAI America XSEL-S User Manual

Page 18

Advertising
background image

1.Outline of Control Method

12

1.1

Communication system

RC Gateway Function can be selected from two types of communication systems and two types of

operation systems.

[1] For SIO type

For XSEL-P/Q/PX/QX Controllers, the slave (RC Controller) is to be connected with RS485

communication system using SIO converter or RS232C Converter Unit.

For XSEL-R/S/RX/SX Controllers, switching over between RS232C and RS485 settings is available

by the system operation setting switches provided on the controller unit. Put it on RS485 setting.

Neither of SIO converter or RS232C Converter Unit is necessary

(Note 1)

and the slave (RC Controller)

can directly be connected.

Ɣ System Configuration Example

XSEL

-P/Q/PX/QX

R/S/RX(D)/SX(D)

SIO converter

or

RS232C

RS485

conversion unit

SCON-C

The RC gateway function can be used only with this connector.

* If the controller is set up to operate in the RC gateway function

mode, this connector cannot be used in any other communication

method.

An error “425: Mount SIO communication mode error” (Purpose of use) will occur.

PCON-SE ACON-SE

ROBONET

(SIO type)

General-purpose RS232C port connector 1

General-purpose RS232C port connector 2

System Operation Switches

(Note 1)

(Note 1) It is not necessary for XSEL-R/S/RX(D)/SX(D).

(Turn ON System Operation Switch No. 2 on the operation panel of XSEL controller.)

Applicable Controller

Controller name

Model No.

Applicable version

XSEL-P/Q

V0.68 or later

XSEL-PX/QX

V0.34 or later

XSEL-R/S

XSEL-RX/SX

X-SEL Controller

XSEL-RXD/SXD

PCON-SE

ACON-SE

SCON-C

ROBONET_SIO type

RC Controller

ERC2-SE

(Note) Network constructing components [Refer to Section 3.2.1.]