IAI America XSEL-S User Manual

Page 21

Advertising
background image

1. Outline of Control Method

15

1.3

Name and Function of Each Part Relating to RC Gateway Function

1.3.1 For SIO type

(1) XSEL-P/Q/PX/QX

[1] +5V supply switch

If a SIO converter is used, set this switch to the left position. (+5V will not be output.)

If a RS232C converter unit (RCB-CV-GW) is used, set the switch to the right position. (+5V will be

output.)

Caution: If the port is used as a standard RS232C port, be sure to set this switch to the left position (so

that +5V will not be output). Failure to do so may cause shorting of the +5V power output circuit

depending on how the connection cable is wired.

[2] RC gateway function connector [S2]

For SIO type, use the general-purposed RS232C Port Connector 2.

Connect to RC Controller and ROBONET using SIO Converter.

Connector

: D-sub, 9-pin (Controller: Male end / Cable: Female end)

Interface standard : RS232C

Pin number

Signal name

Details

1

CD

Carrier Detection (not used)

2

RD

Receive Data

3

SD

Send Data

4

ER

Equipment Ready

5

SG

Signal Ground

6

DR

Data Set Ready

7

RS

Request to Send

8

CS

Clear to Send

9

+5V

RCB-CV-GW Converter Power

[1] +5V supply switch

[2] RC gateway function

connector [S2]

Advertising