3. XSEL-R/S/RX/SX/RXD/SXD

14

3.3.2 Monitor LED indications

LED

Color

Indication

Status

Meaning

Illuminating

Normal Communication Status.

Both input and output are available for the process data.

(EtherCAT® communication in “OPERATION” condition)

Blinking *1

Under configuration condition in mailbox communication.

Process data invalid.

(EtherCAT® communication in “PRE-OPERATION” condition)

Green

Single flash *2

Configuration complete. Refer below for the process data communication.

• Input: Inputting invalid

• Input: Outputs 0 data

(EtherCAT® communication in “SAFE-OPERATION” condition)

Orange Illuminating An error that cannot be recovered (Module error)

RUN

-

OFF

Initial condition (EtherCAT® communication in “INIT” condition)

or the power is OFF

Illuminating An error that cannot be recovered (Module error)

Blinking *1 Network construction error

Orange

Double flash *3 Communication error (Watchdog Timer Timeout�

ERR

-

OFF

No abnormality or the power is OFF

Illuminating Linked (Communication traffic not detected)

Green

Flickering *4 Linked (Communication traffic detected)

Link/

Activity

-

OFF

No link or the power is OFF