Monitor LED

Contents

Cause and Remedy

EE69

EE6C

24V I/O Error

DO Output Current Error

It is generated when the +24V power for I/O is not

supplied. Check the power supply.

(How to start up the controller without connecting

the I/O 24V power)

Set the I/O parameter No.10 to 13 corresponding

to the standard or extended I/O board to “0”. (Note)

I/O cannot be used.

ED5D

Fieldbus Error

This occurs when the network connection is not

established.

Check the parameters on XSEL and the

parameters on PLC.

(Way to boot the controller without connecting to

EtherCAT®)

Set both the I/O parameter No.18 to “0”.

Other Alarm Codes Related to EtherCAT®

� Message Level Error

No.

Error name

Contents / Counteractions

A6B

Fieldbus Error

(FBRS Link Error)

FBRS Link Error was detected.