Appendix

32

� I/O Parameter

No.

Parameter name

Default

(reference)

Input

Range

Unit

Remarks

225 Network I/F Module Control

6H

Only

referring

(HEX)

-

Bit 0 to 3: Type of Network I/F Module

Control 1

(0: Not Mounted

1: CC-Link,

2: DeviceNet,

3: Profibus,

4 to 5: System Reservation,

6: EtherCAT,

7: EtherNet/IP)

Bit 4 to 7: Type of Network I/F Module

Control 2

(0: Not Mounted

1: CC-Link,

2: DeviceNet,

3: Profibus,

4 to 7: System Reservation)

226 Network I/F Module 1

Node Address

17

0 to 65535

-

• At CC-Link : 1 to 64

• At DeviceNet : 0 to 63

• At Profibus : 0 to 125

* Setting establishment not necessary for

EtherCAT (Make setting from master)

227 Network I/F Module 1

Baud Rate

0

0 to 9

-

• At CC-Link:

(0: 156kbps, 1: 625kbps, 2: 2.5Mbps,

3: 5Mbps, 4: 10Mbps)

• At DeviceNet�

(0: 125kbps, 1: 250kbps, 2: 500kbps)

• At EtherNet/IP:

(0: Autonegotiation,

1: 10Mbps (Half-Duplex),

2: 10Mbps (Full duplex),

3: 100Mbps (Half-Duplex),

4: 100Mbps (Full duplex))

* Setting establishment not necessary for

Profibus and EtherCAT

*The the actual default value may differ depending on the construction of used option board.

Advertising