IAI America XSEL-S User Manual

Page 23

Advertising
background image

3. XSEL-R/S/RX/SX/RXD/SXD

17

[4] I/O Port Assignment Classification Setting

Set the I/O port assignment Classification to I/O Parameter No.1.�

No.

Parameter name

Default

(reference)

Input

Range

Unit

Remarks

1 I/O Port Allocation Type

0

0 to 1

-

0: Fixed Allocation

1: Automatic Allocation

• Reference 1

Priority of I/O Port

Assignment when

automatically assigned

Port No.

(No.0 to 299/No.300 to

599)

1)

Network I/F Module 1

2)

I/O slot 1 (I/O1) Mounting board

3)

I/O slot 2 (I/O2) Mounting board

*

Assigned for the range of

continuous mounting from I/O slot 1

(I/O1) Mounting board

• Reference 2

Priority of extension I/O

ports at automatic

assignment

Port No.

(No.1000 to 3999/

No.4000 to 6999)

1)

Network I/F Module 2

2)

Extension I/O Unit

3)

Communication between IA Net

Controllers

Note If the automatic assignment is selected, the input port is assigned to an input port area

(No. 0 to 299).

The output port is assigned to the output port area (No. 300 to 599).

If the fixed assignment is selected, the user will manually assign the input to either of

the standard input port area (No. 0 to 299) or extension input port area (No. 1000 to

3999).

For the output port, the user will manually assign the output to either the standard

output port area (No. 300 to 599) or the extension output port area (No. 4000 to 6999).

[5] Number of I/O Port Setting

Set the number of ports to be used for I/O Parameters No.14 to 15.�

Set a number that is a multiple of 8.�

No.

Parameter name

Default

(reference)

Input

Range

Unit

Remarks

14 Network I/F Module 1

Number of Remote Input Ports

256

0 to 256

- Multiples of 8

15 Network I/F Module 1

Number of Remote Output Ports

256

0 to 256

- Multiples of 8

[6] I/O Port Top Number Setting

Set the top port number of the port range used in I/O Parameters No.16 to 17.

Note The port numbers assigned here are the starting input and output port numbers.

Add the number of ports assigned in parameters 231 and 232 to determine the I/O

range.

The values entered into these parameters must be evenly divisible by 8 (EX: 300)

No.

Parameter name

Default

(reference)

Input

Range

Unit

Remarks

16 Network I/F Module 1

Fix-Allocated Input Port Start No.

1000

-1 to 3999

-

0+(Multiples of 8)(0 to 299)

1000+(Multiples of 8)(1000 to 3999)

(Unavailable when it is negative figure)

17 Network I/F Module 1

Fix-Allocated Output Port Start No.

4000

-1 to 6999

-

300+(Multiples of 8)(300 to 599)

4000+(Multiples of 8)(4000 to 6999)

(Unavailable when it is negative figure)