� Cold Start Level Errors

No.

Error name

Contents / Counteractions

678

Extension I/O Port Assignment

Parameter Error

There is an error in a parameter related to the extended I/O port

assignment.

679

Extended I/O Port Assignment Number

Overflow Error

The number of extended I/O port assignment exceeded the

specification range.

67A

Extended I/O Port Duplicated

Assignment Error

Extended I/O port assignment has duplicated.

D56

Fieldbus Error

(MinACK Timeout)

The Min ACK Timeout was detected.

Refer to the operation manual of the field network board and

check the conditions of monitoring LEDs on the front of the

board.

D59

Fieldbus Error

(DPRAM Writing and Reading)

The DPRAM writing and reading error was detected.

Refer to the operation manual of the field network board and

check the conditions of monitoring LEDs on the front of the

board.

D5A

Fieldbus Error

(TOGGLE Timeout)

The TOGGLE Timeout was detected.

Refer to the operation manual of the field network board and

check the conditions of monitoring LEDs on the front of the

board.

D5B

Fieldbus Error

(Access Right Retry Over)

The Access Right Retry Over Error was detected.

Refer to the operation manual of the field network board and

check the conditions of monitoring LEDs on the front of the

board.

D5D

Fieldbus Error

(FBRS Link Error)

The FBRS Link Error was detected.

Refer to the operation manual of the field network board and

check the conditions of monitoring LEDs on the front of the

board.

D5E

Fieldbus Error

(Mail BOX Response)

The Mail BOX Response Error was detected.

Refer to the operation manual of the field network board and

check the conditions of monitoring LEDs on the front of the

board.

D5F

Network I/F Module Class Mismatch

Error

The type of I/F module specified in I/O Parameter No.225 and

the type of network module actually mounted do not match.

Check the setting in I/O Parameter No.225 and the combination

of network I/F module actually mounted.

D75

Fieldbus Parameter Error

There is a failure in the Fieldbus Parameter. Check in I/O

Parameters No.226.

D77

Fieldbus Error

(Exception)

The Exception Error was detected.

Refer to the operation manual of the field network board and

check the conditions of monitoring LEDs on the Fieldbus.

E1F

I/O Assignment Parameter Error

It can be concerned that a value other than the input and output

port number (-1 is acceptable) or a value other than Input and

Output Board Top No. + [a multiple of 8] is input in I/O

Parameter No.2 to�9, or a value other than [a multiple of 8] is

input in I/O Parameter No.14 to 17.

E20

I/O Duplication Assignment Error

I/O assignment is duplicated. Check I/O Parameter No.2 to 9,

14 to 17, card model code (input and output number) in the slot

and so on.

E21

I/O Assignment Number Overflow Error

I/O assignment has exceeded the specified range. Check I/O

Parameter No.2 to 9, 14 to 17, card model code (input and

output number) in the slot and so on.

E8F

Fieldbus Logic Error

It is a logic error at the Fieldbus initializing.