3. XSEL-R/S/RX/SX/RXD/SXD

20

No.

Parameter name

Default

(reference) Input Range Unit

Remarks

16 Network I/F Module 1

Fix-Allocated Input Port Start No.

1000

-1 to 3999

0

0+(Multiples of 8) (0 to 299)

1000+(Multiples of 8) (1000 to 3999)

[Unavailable when it is negative figure]

17 Network I/F Module 1

Fix-Allocated Output Port Start No.

4000

-1 to 6999

300

300+(Multiples of 8) (300 to 599)

4000+(Multiples of 8) (4000 to 6999)

[Unavailable when it is negative figure]

18 Network I/F Module 1

Error Monitor

1

0 to 5

1

0:

No Monitoring (Not to use Network I/F

Module 1)

1:

Monitoring

120 Network Attribute 1

640001

H

0 to

FFFFFFFF

H

Opti-

onal

Bit 16 to 23:

Value of Link Timeout at initializing

(Example) Default 64

H

= 10sec

Bit 28 to 31: Network I/F Module 1

Input port data select for link

error

(0: Clear, 1: Hold)

225 Network I/F Module Control

*6

00

H

to 37

H

06

Bit 0 to 3:

Type of Network I/F Module Control 1

6: EtherCAT

Bit 4 to 7:

Type of Network I/F Module Control 2

0: Not Mounted

1: CC-Link

2: DeviceNet

3: PROFIBUS

226 Network I/F Module 1

Node Addres

17

0 to 65535 Opti-

onal

EtherCAT: 0 to 65535

(Make setting from master)

231 Network I/F Module 2

Remote Input Ports

0

0 to 256

0 8 port unit

232 Network I/F Module 2

Remote Output Ports

0

0 to 256

0 8 port unit

233 Network I/F Module 2

Extension Input Port Start No.

-1

-1 to 299

1000 to 3999

-1

0+(Multiples of 8)

or

1000+(Multiples of 8)

[Ineffective when -1 is selected]

234 Network I/F Module 2

Extension Output Port Start No.

-1

-1

300 to 599

4000 to 6999

-1

300+(Multiples of 8)

or

4000+(Multiples of 8)

[Ineffective when -1 is selected]

235 Network I/F Module 2

Error Monitoring

1

0 to 5

0

0: No Monitoring

(Not to monitor condition of link to PLC

(master))

1: Monitoring