4.

Appendix

28

4. Appendix

4.1 Troubleshooting

(1) In case it is not possible to connect the network, check the current condition on the display of

monitoring LEDs of EtherCAT® Board. [Refer to Section 3.3.2.]

Check the settings of the XSEL controller and the settings of the master unit referring to the

operation manuals of the master unit.

(2) When an alarm is issued, an alarm code gets output to the panel window of the XSEL

controller.

1) Based on the read alarm code, search the alarm description list in the operation

manual for the XSEL controller.

2) Deal with it based on the description for the alarm code in question.

The alarm codes listed below are those you will often see in the startup process.

Alarm Codes in Common with XSEL

Monitor LED

Contents

Cause and Remedy

ErG

Emergency Stop

It is not an alarm.

This occurs when the emergency stop switch of a

teaching tool such as the PC software is not

released.

• It is generated when the personal computer

cable is not connected to the emergency stop

switch box.

• Check the emergency stop circuit.

Enb

Safety Gate Remains

Opening

Deadman Switch OFF

It is not an alarm.

• It is generated when the system I/O ENB signal

is opened. Check the ENB signal.

(It is generated when the safety gate is open.

Close the safety gate.)

• This occurs when AUTO/MANU switch is on

MANU and no teaching tool such as a PC is

connected. Connect the teaching pendant or set

the AUTO/MANU switch to “AUTO”.

• When the actuator is to be started up, hold the

deadman switch on the teaching pendant to turn

it ON.

ACF

AC Power Interruption

Momentary Power Failure

Power Voltage Drop

The power voltage is not supplied properly.

Check the power supply.

E914

Absolute Data Backup

Battery Voltage Error

It will be generated in the case that the battery has

not been attached, or the battery voltage is

dropped.

In the case of the actuator for the single-axis

robots or orthogonal robots with the absolute data

specifications, it is generated when the power is

connected for the first time.

Perform the absolute reset.

ED12

Encoder Disconnection

Error

It is generated when the cable is broken or the

encode cable is not connected to the controller.

Check the wiring.

ED19

Encoder Reception Time

Out

It is generated when the encoder is broken down,

the cable is broken or the encoder cable is not

connected to the controller.