IAI America XSEL-S User Manual

Page 24

Advertising
background image

3. XSEL-R/S/RX/SX/RXD/SXD

18

[7] EtherCAT® Board Use Setting

Set “1” (Monitoring: use EtherCAT® board) to I/O Parameter No.18.

No.

Parameter name

Default

(reference)

Input

Range

Unit

Remarks

18 Network I/F Module 1

Error Monitor

1

0 to 5

-

0: No Monitoring (Not to use

EtherCAT®

board)

1: Monitoring (

use

EtherCAT® board)

[8] Time Setting to Wait for EtherCAT® Communication Establishment

Set the maximum allowable time for the establishment of EtherCAT® communication at the

startup in bits 16 to 23 of I/O Parameter No.120. Change this setting when XSEL starts faster

than the master unit, which results in a generation of “D5D” or “A6B”.�

No.

Parameter name

Default

(reference) Input Range Unit

Remarks

120 Network Attribute 1

640001

H

0H to

FFFFFFFF

H

100

msec

Bit 16 to 23: Value of Link Timeout at

initializing

(Example) The initial value 640001

H

is

Bit 16 to 23 = 64

H

= 100

(in 100ms unit)

100×100ms = 10sec

It waits for 10sec at

maximum from the startup

for the communication

establishment.

[9] Data Retaining Setting at EtherCAT® Communication Error

Set whether to clear the input port data with 0 or to retain when an error is generated in bits 28

to 31 of I/O Parameter No.120.�

No.

Parameter name

Default

(reference) Input Range Unit

Remarks

120 Network Attribute 1

640001

H

0H to

FFFFFFFF

H

Bit 28 to 31: Network I/F Module 1

Input port data select for link

error

(0: Clear, 1: Hold)