3. XSEL-R/S/RX/SX/RXD/SXD

15

3.4 Wiring

3.4.1 Wiring (example)

PLC (EtherCAT® Master Unit)

* EtherNet Cable: Straight cable of category 5 or more, 100m max.

(Aluminum tape and braided double-shielded cable are recommended.)

Note 1 Only the daisy chain is supported in the network topology.

Note 2 There are IN and OUT designated for the communication port for EtherCAT®. Be

careful not to plug in the communication cable in the wrong way.

Note 3 Terminal processing is not required.

3.4.2 Connector Pin Layout

Pin No.

Signal Name

Signal Abbreviation

1

Data transmitted +

TD+

2

Data transmitted -

TD-

3

Data received +

RD+

4

Not used

5

Not used

6

Data received -

RD-

7

Not used

8

Not used

Connector

Hood

Grounding pin for security

FG

XSEL-R

EtherNet Cable *

EtherNet

Cable *

8

1

RJ45 8-pin

Module Connector

(Controller Side)

XSEL-S

EtherNet

Cable *

OUT

Connector

IN

Connector

OUT

Connector

IN

Connector

Other

Slaves