14

INTELLIGENT ACTUATOR

Chapter 1 Installation

2.

Speci

¿

cations

2. Specifications

2.1

Basic Specifications

Item

Description

Number of controlled axes

Maximum 3 axes (Factory setting)

Power-source voltage

Single-phase, 100 to 230 VAC 10%

Power-source frequency

50 Hz/60 Hz

Withstand voltage

2000 V 1 minute

Rush current

15 A (100 VAC), 30 A (200 VAC)

Leak current

0.75 mA (60 Hz)

Resistance to momentary power failure

Max 500 s

Electric-shock protection mechanism

Class 1 basic isolation

Surrounding air temperature range

5 C to 40 C

Surrounding humidity range

20% to 90% (Non-condensing)

Storage temperature range

-10 C to 65 C

Maximum speed

300 mm/sec

Rated acceleration

Gate type: 0.3G, Cantilever type: 0.2G

Programming language

Super SEL language

Program steps

6000 steps (total)

Number of positions

3000 positions

Number of programs

64 programs

Multi-tasking

16 programs

Standard inputs

16 points (General-purpose inputs, port Nos. 016 to 031)

Standard outputs

16 points (General-purpose outputs, port Nos. 316 to 331)

Dedicated inputs

Digital switch for program number input
Function switch, etc.

Dedicated outputs

Alarm status indicator LED
Ready status indicator LED
Emergency-stop status indicator LED
Home-return completion status indicator LED, etc.

Serial communication

For teaching pendant/PC connection

Supported Fieldbus standards

CC-LINK DeviceNet Profibus

ModBus/TCP Ethernet

Note: The parameters are normally set to the above general-purpose input and general-purpose output