Parameters Common to All Axes

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

28

Selection of inching

o

jog auto-switching
prohibition

0

0 to 5

0: Execute auto-switching (Continuous button ON timer), 1:

Prohibited
* Referenced by the PC/TP. (Handy terminal automatic

switching function is not available.)

29

All-axis setting bit
pattern 1

0

0H to

FFFFFFFFH

Bits 0 to 3:

Selection of use of last PC/TP inching distance
(0: Do not use, 1: Use)
* Referenced by the PC/TP

(Excluding ANSI-compatible TP)
(PC software version 2.0.0.42 or later or TP

application version 1.09 or later).

Bits 4 to 7:

Overrun (servo) error level (0: Operation-
cancellation level, 1: Cold-start level, 2:
Operation-cancellation level at reset, thereafter
cold-start level)

Bits 8 to 11:

“Actual-position soft limit over (servo)” error
level (0: Operation-cancellation level, 1: Cold-
start level, 2: Operation-cancellation level at
reset, thereafter cold-start level)

30

Default division angle

150

0 to 1200

0.1

degree

(“0” can be input in PC software version 1.1.1.0 or later or TP
application version 1.06 or later)

31 Default

division

distance

0

0 to 10000

mm

(“0” can be input in PC software version 1.1.1.0 or later or TP
application version 1.06 or later)

32 Arch-trigger

start-point

check type

0

0 to 5

0: Check operation amount and actual position, 1: Check

operation amount only

33

Safety speed in
manual mode

250

1 to 250

mm/s

* This parameter is treated as a value equivalent to or below

the minimum value set in “Axis-specific parameter No. 29,
VLMX speed” for all valid axes.

34 to

50

(For expansion)

0

a

PC: PC software
TP: Teaching pendant