IAI America SSEL User Manual
Page 176
Advertising

154
Part 2 Programs
z GVEL (Get speed data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
GVEL
Variable
number
Position
number
CP
[Function] Obtain speed data from the speed item in the position data specified in operand 2, and set
the value in the variable specified in operand 1.
[Example]
GVEL
100
10
Set the speed data at position No. 10 in variable 100.
Position Data Display in PC Software
No.
Axis 1
Axis 2
Vel
Acc
Dcl
1
2
x
x
x
10 50.000 100.000 200 0.30 0.30
x
x
If the position data is set as above when the command is executed, 200 will be set in variable 100.