Chapter 2 specifications, Controller specifications – IAI America SSEL User Manual

Page 28

Advertising
background image

6

Part 1 Installation

Chapter 2 Specifications

1. Controller

Specifications

Base specifications of this product

100-V input specification

200-V input specification

Total output when maximum
number of axes are connected

400 W

800 W

Control power input

Single-phase 100 to 115 VAC

r 10% Single-phase 200 to 230 VAC r 10%

Motor power input

Single-phase 100 to 115 VAC

r 10% Single-phase 200 to 230 VAC r 10%

Power-supply frequency

50/60 Hz

r 5%

Resistance against momentary
power failure

0.5 cycle (Not dependent on phase)

Withstand voltage

1500 VAC for 1 minute *1

Insulation resistance

500 VDC, 100 M

: or more

Leak current

Controller alone (no actuator connected): 1.0 mA max.

Drive-source cutoff method

Internal relay

Emergency stop input

Contact B input (Internal power-supply type)

Emergency stop action

Deceleration stop + Regenerative brake by timer

Enable input

Contact B input (Internal power-supply type)
AC full digital servo

Control method

Incremental serial encoder
Absolute serial encoder

Position detection method

ABZ (UVW) parallel encoder
Absolute-data backup battery/system-memory backup battery (Optional)

Battery

Lithium battery: AB-5 by IAI, 3.6 V/2000 mAh

Programming language

Super SEL language
Controller with increased memory size

9999 steps (total)

Number of program steps

Controller without increased memory size

2000 steps (total)

Controller with increased memory size

20000 positions (total)

Number of positions

Controller without increased memory size

1500 positions (total)

Controller with increased memory size

128 programs

Number of programs

Controller without increased memory size

64 programs

Multi-tasking capability

8 programs

Storage device

Flash ROM

Data input method

Teaching pendant or PC software
24 VDC

r 10%

Electromagnetic brake power

2 A peak (1 A peak/axis)

Electromagnetic brake output
voltage

45 VDC (90 V at over-excitation)

PIO power input

24 VDC

r 10%

Category B (Built-in relay)

Safety category

* Safety category 1 can be met by connecting an external safety relay, etc.

Regenerative resistor

20 W, built-in (External resistance unit(s) can be connected.)

PIO inputs

24 points, NPN or PNP (Selectable as factory setting)

PIO outputs

8 points, NPN or PNP (Selectable as factory setting)

Air cooling method

Forced air-cooling

Weight 1380

g

100 (W) x 195 (H) x 126 (D); mounting pitch 186 mm

External dimensions

202.6 (H) if the absolute-data backup battery holder is installed.
I/O flat cable
Power connector
EMG connector

Accessories

ENB/BK connector

*1)

The withstand voltage of the motor used in each actuator is 1,000 VAC for 1 minute. If withstand voltage test is performed with
the controller connected to an actuator, ensure that voltage exceeding 1,000 VAC will not be applied for more than 1 minute.

Advertising