409

Appendix

(2)

Output

Function List

Output function

specification

value

Function name

Remarks

0 General-purpose

output

1

Operation-cancellation level or
higher error output (ON)

* The following output functions cannot be assigned at the same time:

• Operation-cancellation level or higher alarm output (ON) (Output function

specification value = 1)

• Operation-cancellation level or higher alarm output (OFF) (Output function

specification value = 2)

• Operation-cancellation level or higher alarm + emergency stop output (ON) (Output

function specification value = 3)

• Operation-cancellation level or higher alarm + emergency stop output (OFF) (Output

function specification value = 4)

2

Operation-cancellation level or
higher error output (OFF)

(Same as “Output function specification value = 1”)

3

Operation-cancellation level or
higher error + emergency stop
output (ON)

(Same as “Output function specification value = 1”)

4

Operation-cancellation level or
higher error + emergency stop
output (OFF)

(Same as “Output function specification value = 1”)

5

READY output (PIO trigger
program operation enabled)

* The following output functions cannot be assigned at the same time:

• READY output (PIO trigger program operation enabled) (Output function

specification value = 5)

• READY output (PIO trigger program operation enabled AND absence of operation-

cancellation level or higher error) (Output function specification value = 6)

• READY output (PIO trigger program operation enabled AND absence of cold-start

level or higher error) (Output function specification value = 7)

6

READY output (PIO trigger
program operation enabled AND
absence of operation-
cancellation level or higher
error)

(Same as “Output function specification value = 5”)

7

READY output (PIO trigger
program operation enabled AND
absence of cold-start level or
higher error)

(Same as “Output function specification value = 5”)

8

Emergency stop output (ON)

* The following output functions cannot be assigned at the same time:

• Emergency stop output (ON) (Output function specification value = 8)
• Emergency stop output (OFF) (Output function specification value = 9)

9

Emergency stop output (OFF)

(Same as “Output function specification value = 8”)

10

AUTO mode output

11

Auto operation status output

(Other parameter No. 12)

12

All-valid-axes home (= 0) output * To move the absolute-encoder axis to coordinate 0 or the preset home coordinate, use

a MOVP command instead of a HOME command.

13

All-valid-axes home return
complete (coordinate confirmed)
output

* To move the absolute-encoder axis to coordinate 0 or the preset home coordinate, use

a MOVP command instead of a HOME command.

14 All-valid-axes

preset

home

coordinate output

* To move the absolute-encoder axis to coordinate 0 or the preset home coordinate, use

a MOVP command instead of a HOME command.

15

Voltage-low warning output for
system-memory backup battery

16

Voltage-low warning output for
absolute-data backup battery

All axes are checked by the OR gate. Once an abnormal level has been detected, the
signal will remain ON until a power ON reset or software reset is performed.

17

Drive-source cutoff (SDN)
notification output

The output port will turn OFF when the drive source is cut off.
(* Caution: This notification output is implemented only by software means.)

18 For

future

expansion

19 For

future

expansion

20 ~ 23

For future expansion

24

Axis 1 servo-ON status output

25

Axis 2 servo-ON status output

26 ~ 29

For future expansion

The following assignments are prohibited:
• Assign a specification value not included in the I/O function lists.
• Assign the same input function specification value, which is not for general-purpose input, to multiple input ports.
• Assign the same output function specification value, which is not for general-purpose output, to multiple output ports.
(For the conditions associated with each specification value, refer to the Remarks field of the applicable item.)

If a prohibited assignment is set, an error “I/O function assignment error” will generate and all input ports and output ports will become
general-purpose inputs and general -purpose outputs, respectively.
* In the positioner mode, input and output function assignments are ignored. Each function will follow the corresponding specification in the

positioner mode.