Teledyne LeCroy SierraFC M164 User Manual User Manual
Page 86

Teledyne LeCroy
Easy Mode (Pre‐Defined Setups)
86
SierraFC M164 Protocol Analyzer User Manual
FCAE‐FCP SCSI Command ‐ RDMA With Target Notification
Double‐click FCAE RDMA FCP SCSI Command‐With Target Notification in the Patterns
Library panel to open thee Add FCAE RDMA FCP SCSI Command‐With Target Notification
dialog.
Figure 2.51: FCAE FCP-RDMA SCSI Command With Target Notification Dialog
The format can be Binary or Hexadecimal.
If you select Any SCSI Command, the Command Type can only be Any Command. Click
the down arrow next to the CDB dropdown list, scroll the list to choose a CDB Type, and
click OK. The Any option allows specifying any vendor‐specific or other command.
If you select MMC‐6, SBC‐3, SMC‐3, SPC‐4, SSC‐2, OSD‐2, or ADC‐3, click the down arrow
next to the Command Type dropdown list, scroll the list to choose a Command Type, and
click OK.