4 dual rs-232 cable with slot bracket, Figure 4-7: ide cable connection – IEI Integration PCISA-945GSE v1.10 User Manual
Page 79

PCISA-945GSE CPU Card
Page 61
Step 2:
Insert the connector. Connect the IDE cable connector to the onboard
connector. See
7
Figure 4-7. A key on the front of the cable connector ensures it
can only be inserted in one direction.
Figure 4-7: IDE Cable Connection
Step 3:
Connect the cable to an IDE device. Connect the two connectors on the other
side of the cable to one or two IDE devices. Make sure that pin 1 on the cable
corresponds to pin 1 on the connector.
Step 0:
4.9.4 Dual RS-232 Cable with Slot Bracket
The dual RS-232 cable slot connector consists of two connectors attached to two
independent cables. Each cable is then attached to a D-sub 9 male connector that is
mounted onto a slot. To install the dual RS-232 cable, please follow the steps below.
Step 1:
Locate the connectors. The locations of the RS-232 connectors are shown in
Chapter 3.