Watlow Series 935A User’s Manual

Setting Inputs and Outputs

Key Input/Output Set-up Information

All initial input and output set-up occurs in the Configuration Menu.

The 935A requires a thermocouple or RTD input connection to the S1 and S2 Terminals, including
when using the remote set point

[`rSP]

option.

Remote Set Point

[`rSP]

is a second input, wired to OT1 Terminals 3 and 4.

Indication of °C or °F units of measure occurs only in the

[`C_F]

prompt.

Sensor input type minimum and maximum range (see p. 51) is further defined with Range Low

[``rL]

and Range High

[``rh]

to set the working span of set points and remote set point scal-

ing.

Output 1 and Output 2 configure the prime functions of the Series 935A, they are the “golden”
prompts.

Output 1 must be heat or cool to use Output 2 as a timer.

Remote Set Point

[`rSP]

enables Output 1 to act as an input for 0-5

Î

(dc) from another con-

troller or a transmitter.

Front Panel Lock

[`FPL]

requires an external switch and 62

0.5 watt resistor wired in parallel

on Output 1. Switch open = unlocked; closed = locked. See p. 23.

Output 2 sets timer interval in hours:minutes

[thM]

or minutes:seconds

[tMS]

.

Display Default

[dISP]

lets you choose the primary (last 2 characters) and secondary (first 2

characters) default displays. Press

ß

to toggle to the secondary display for 15 seconds.

[``Ac]

= Normal Display: Actual Temperature

Secondary: None

[AcSP]

= Normal Display: Set Point Temperature

Secondary: Actual Temperature

[Acti]

= Normal Display: Time Remaining

Secondary: Actual Temperature

[TiAc]

= Normal Display: Actual Temperature

Secondary: Time Remaining

[tiSP]

= Normal Display: Set Point Temperature

Secondary: Time Remaining

Configuration Menu

[``In]

Input Type

[`C_F]

Celsius/Fahrenheit

[``rL]

Input Range Low

[``rh]

Input Range High

[`Ot1]

Output 1 Function

[`Ot2]

Output 2 Function

[dISP]

Display Default

[ALty]

Alarm Type

[AhYs]

Alarm Hysteresis

[`LAt]

Alarm Latch

[`SIL]

Alarm Silencing

[FAIL]

Failure Mode

[tIM]

Timer Function

[Strt]

Start Timer

[`rdY]

Timer Ready Band

[``St]

Signal Time

[SLOC]

Set Point Lockout

[`tAG]

Lockout Tag