Registering the d8 with the watlow eds file, Registering the d8 with the watlow eds file 48, Figure 3.2—the d8 registered in rsnetworx 48 – Watlow Series D8 User Manual
Page 66: Table 3.1—number of bytes 48

Chapter 3: Communicating by DeviceNet
Series D8 User’s Guide
48
Watlow Anafaze
Doc. 0600-3120-2000
Table 3.1
Number of Bytes
Figure 3.2
The D8 Registered in RSNetWorx
Registering the D8 with the Watlow EDS File
There are important differences between the results of regis-
tering the D8 controller with and without the Watlow-sup-
plied EDS file, though these differences are not readily visible
in Figure 3.2.
Double-clicking node address 1 (D8 controller) in the RSNet-
Worx graph of the network opens the dialog box shown at the
left in Figure 3.3. When the controller is registered with the
Watlow EDS, the same dialog box has an additional tab la-
beled Parameters as shown at the right in the figure.
Controller
Input Bytes
Output Bytes
D84 (4-loop)
41
12
D88 (8-loop)
81
24