background image

Relay Output

Function:

High and low flowrate alarms based on the
flowrate selected as the default display.

Maximum Switching Power:

1250VA.

Maximum Switching Voltage: 250 VAC, 30VDC.
Maximum Switching Current: 5 Amps.

RS232/422/485 Option

Type:

Both RS232 & RS422/485 are provided.

Function:

Printer and computer protocols are
programmable.

Output:

Output is on request or at a programmable
time interval.

Baudrate:

300 to 9600.

Data Bits:

7 or 8.

Parity:

None, Odd, Even.

Pulse Output

Function:

The pulse output is scaled and outputs one
pulse each time the Default total increments
by one digit.

Pulse Width:

10mSec (negative going pulse).

Duty Cycle:

Maximum of 49 pulses per second.

Output:

An open collector transistor will sink 100mA
maximum.

Ideal Gas

Display:

Corrected Volume (m

3

or ft

3

).

Mass (kg or lbs).

Temperature Range:

-273°C (-450°F) to 800°C (1472°F).
(RTD has a more limited range.)

Pressure Range:

0 kPa abs (0 psia) to 100,000 kPa (10,000
psia).