Yokogawa 415 Steam and Gas User Manual

Page 63

Advertising
background image

Flowrate Decimal

The number of decimal points with which the

flowrate is displayed.

Total Decimal

The number of decimal points with which the
total is displayed.

Temperature Offset

This allows a small offset to be programmed to
correct for any offset error in the RTD. For
example, if during "TEST" the temperature was
read at 125.3°C when it was known that the
actual temperature was really 124.8°C, then an
offset of -0.7°C could be programmed to correct
for the error in the RTD.

Pressure Input

Both absolute and gauge pressure systems can
be used with the Model 415.

Atmospheric

Pressure

If a gauge pressure sensor is used, the

atmospheric pressure must be programmed
since this will vary with the altitude of the
installation.

Note that the Absolute Pressure = Atmospheric
Pressure + Gauge Pressure. The atmospheric
pressure will default to 101.325 kPa (14.696
psia) which is the standard value at sea level.

Calibration 61

Advertising