4.1 THE 4-20mA OUTPUT OPTION

The 4-20mA output option provides an analog output of the Default flowrate as
either a 4-20mA current or a 0-10 Volt level. The output will be the corrected
volume, mass or energy, depending on which parameter is programmed as the
default displayed. All output signals are electrically isolated from the instrument
power supply and signal inputs to ensure minimum interference.

Either 2 wire current transmission is available with the loop powered internally,
or 3 wire transmission from an external loop supply.

A block diagram of the output is shown below and various methods of
interconnection are outlined on the following pages.

Options 39

DC to DC
Convertor

Digital to

Analog
Convertor

Opto-Isolation

Amplifiers

0V

-12V

21

23

Terminal

26

25

+15V

24

0-10V Out

22