PROGRAMMING THE FLOW COMPUTER

For equations 11 to 18 to work, a number of parameters need to be
programmed. These include:

K

F

K-factor (for frequency producing flowmeters).

S

M

Span (for analog flowmeters).

ν

B

Base specific weight at which the span is determined.

The flowmeter will measure the flow input A (normalised between 0
and 1) and the temperature T

F

and pressure P

F

. The temperature and

pressure are used to calculate the specific weight,

ν

, and enthalpy, h,

from internal equations. Other parameters must also be programmed
and these are fully detailed in section 5.

Example 7

A vortex flowmeter has a K-factor of 68.32 pulses/ft

3

, and it is

required to measure saturated steam in lbs/hour. What are the
main parameters to be programmed?

The instrument should be programmed for steam measurement
from a frequency meter. Because the steam is saturated, it is only
necessary to use either a temperature or pressure sensor. Because
of cost, a temperature probe is used. The main parameters to
program are simply:

Units

US Units

K-factor

=

68.32

Timebase

hours