Connection of Output Pulse is as follows:

Driving an External Relay or Impulse Counter

Driving a Logic Input such as a PLC or Electronic Counter

38 Operation

11

DC Supply
Out (8-24V)

Model 415

5.6 ohms

33V
Zener

2

External Load
Resistor 10K

Logic Input

10

Model 415

5.6 ohms

33V
Zener

12

DC Supply

Relay or
Impulse Counter