Coupling
(Edge, Delay)

DC

DC coupling.

AC

AC coupling. Blocks DC components
from the trigger circuits.

HF reject

High frequency filter above 50kHz

LF reject

Low frequency filter below 50kHz

Reject noise

DC coupling with low sensitivity to
reject noise.

Slope
(Edge, Delay, Rise
& Fall)

Trigger on a rising edge.

Trigger on a falling edge.

Don’t care.
(Rise & Fall trigger type only)

Trigger Level
(Edge, Delay)

Level

Adjusts the trigger
manually using the
Trigger LEVEL knob.

LEVEL

Set to TTL
1.4V

Sets the trigger level to 1.4V, suitable
for triggering on TTL signals.

Set to ECL -
1.3V

Sets the trigger to -1.3V. This is
suitable for ECL circuits.

Set to 50%

Sets the trigger level to
50% of the waveform
amplitude.

50%

Holdoff

Holdoff

Sets the holdoff time.

Set to
Minimum

Set the holdoff time to the minimum.