Operation, 2 log files – KROHNE OPTISONIC 6300 P-6400 EN User Manual
Page 60

6
OPERATION
60
OPTISONIC 6300 P
www.krohne.com
03/2013 - 4000972603 - MA OPTISONIC 6300 P R03 en
6.4.2 Log files
Log files can be managed on the converter itself. You can rename, copy or delete log files. You
can find this option in the file management menu (4.2). All log files are stored on the converter as
binary files.
With the import and export function you can transfer the log files in their original format.
The Export to CSV option is only possible when a memory stick is connected to the converter.
The converter exports the log files to the memory stick as a CSV (Comma Seperated Value) file.
File management Log files
Import
Rename
Copy
Export
Delete
Export to CSV
13-04-2010 14:11:09 13 MB free
INFORMATION!
The value's in the log file are separated with a ";" and "." is used as a decimal separator. A
thousands separator is not used. Use the correct settings in Excel during the import of a CSV file.
CAUTION!
Make sure that log files have a valid name: minimum one character, maximum 12 characters
and underscores (_) are not allowed.