4.4

Connection examples

only with 6-wire bridge

After initialization, a test for connection of the sense signal is made automatically (6-wire connections )

Electrical connections

14

Connection examples

SG 45

1

4 EX-

Excitation-

Excitation+

Ausgang

EX+

5 INP +

6 INP -

3 SENSE -

2 SENSE +

Sense+

Sense-

+SENSE-

+ INP -

EX+

EX-

Example: Connection load cell with 4 or 6-wire bridge

1

4 EX-

5 INP +

6 INP -

3 SENSE -

Excitation

Excitation

Ausgang

EX+

R-CAL

+SENSE-

+ INP -

EX+

EX-

Example: Connection of a (melt) pressure sensor in 4-wire technology with a calibrating resistor

Master z.B. / e.g.

Converter RS 232-RS 485

(ADAM-4520-D)

DATA+ 1
DATA-

TX+

TX-
RX+

RX-

(R)+Vs
(B)GND 10

Data A

Data A

Data B

Data B

RGND

(RS-485)

(RS-422)

LT

LT

Example: RS 485 interface with RS 485-RS 232 converter
See documentation 9499-040-72011