System interface 39, Fnc1, Fnc.2 – West Control Solutions SG 45 User Manual

Page 39: Fnc.3, S.typ, S.lin, In.f, Fnc.1 (fnc.2) (fnc.3), Src.1 (src.2) (src.3)

Advertising
background image

7.3

Configurations

Dependent on device version und adjusted configurations values not needed become hidden.

µ Entrys marked with this symbol are selectable only with existing device-option.

Selection of functions Func

Name

Value range

Description

Fnc1

Function 1

0

No function

1

Zero setting

Fnc.2

Function 2

0

No function

3

Tare

Fnc.3

Function 3

0

No function

2

Sample & Hold

3

Integrator

Input INP

Name

Value range

Description

S.tYp

Sensor type

60

0,5 mV/V

61

1 mV/V

62

2 mV/V

63

4 mV/V (the selection for sensors with 3,33mV/V)

S.Lin

Linearization

0

No linearization

1

Special linearization

In.F

Alternative value

Limit values Lim1 … Lim3

Name

Value range

Description

Fnc.1

(Fnc.2)
(Fnc.3)

Function of limit 1 (2, 3)

0

Switched off

1

Measurement value

2

Measured value monitoring + alarm status latch. A stored limit value can be reset
via error list or a digital input (

® LOGI/ Err.r).

3

Signal change (in minutes).

4

Signal monitoring for rate of change (per minute) + storage of the alarm status. A sto-
red limit value can be reset via error list or a digital input (

® LOGI/ Err.r).

Src.1

(Src.2)
(Src.3)

Source of limit 1 (2, 3)

0

process value = displayed value

3

Measured value INP

12

Zero offset (difference between the calibrated zero and the value at the time of
zero setting)

C.Std

OFF; 1 …

9999999

Control operating hours (only visible with BlueControl

Ò

!)

C.Sch

OFF; 1 …

9999999

Control switching cycles (only visible with BlueControl

Ò

!)

Configuration level

39

Configurations

SG 45