Analog output wiring diagrams – Badger Meter M-Series M3000 User Manual

Page 15

Advertising
background image

15

Terminal 6 – Ground from external counter device
connected to terminal 5

Terminal 7 – RS485 A –

Terminal 8 – RS485 B –

Terminal 9 – Analog Output –

Terminal 10 – Common fi eld ground

Terminal 11 – RS232 OUT –

Terminal 12 – RS232 IN –

Terminal 13 – Output 3 (+) Solid state relay output
Functions: preset output, fl ow set point, error alarm, empty
pipe error, fl ow direction

Terminal 14 – Output 3 (-)

Terminal 15 – Output 4 (+) – Solid state relay output
Functions: preset output, fl ow set point, error alarm, empty
pipe error, fl ow direction

Terminal 16 – Output 4 (-)

Auxiliary Input Wiring Diagram

Function: Reset
Positive

Zero

Return

+18VDC 1

Input 1 (+)

2

Normally Open
Contact

Input 1 (+)

2

Common 4

5-24VDC

_____________________________________________

Analog Output Wiring Diagrams

• Analog Output (Loop voltage = 18VDC Sourced, 750 MAX)

Function: 4-20mA
0-20mA
0-10mA

mA Analog Output (+) 9

Common 10

_____________________________________________

Functions:

Forward (only) Pulse

AMR

Pulse

Flow

Set

Point

Error

Alarm

Empty

Pipe

Flow

Direction

Output 1 (+)

3

Common 4

02

01

+

External Counter
Badger Meter ER8
or AMR Device

Active Output Wiring

Output 1 (+)

3

Common 4

External
Counter

0 +

0 —

+18VDC 1

10k Resistor (Not Supplied)

}

Programmable

• Output 1

Transistor Output (open collector)

24VDC

Max

.5W

Max


Passive Output Wiring

_____________________________________________

• Output 2

Transistor Output (open collector)

24VDC

Max

.5W

Max


Passive Output

Functions:

Reverse (only) Pulse

Frequency

Output

Preset

Output

Flow

Set

Point

Error

Alarm

Flow

Direction

}

Programmable

Output 2 (+)

5

Common 6

02

01

+

External Counter
Badger Meter ER8
or AMR Device

Active Output

Output 2 (+)

5

Common 6

External

Counter

0 +

0 —

+18VDC 1

10k Resistor (Not Supplied)

_____________________________________________

Functions: Preset

Output

Flow

Set

Point

Error

Alarm

Empty

Pipe

Error

Flow

Direction

Output 3 (+)

13

Output 3 (-)

14

+24VDC

+

• Output 3

Solid State Relay Output

24V AC/DC Max

500mA

Max

Alarm

Indicator

_____________________________________________

• Output 4

Solid State Relay Output
24V AC/DC Max
500mA Max

Output 4 (+)

15

Output 4 (-)

16

+24VDC

+

Alarm

Indicator

Functions: Preset

Output

Flow

Set

Point

Error

Alarm

Empty

Pipe

Error

Flow

Direction

External Disconnect

Position this device in an accessible location.

Position and identify the disconnect device so as to provide
safe and easy operation.

Label the disconnect device as being for the Mag Meter.

Install an external disconnect switch or circuit breaker that
meets local standards.

AC/DC Power Wiring
For AC/DC power use three wire, sheathed, cable with cable
diameter of 18 AWG (not supplied).

AC/DC wire insulation temperature class must not exceed
the maximum ambient temperature of its location.

Use conduit and conduit fi ttings (not supplied) that are rated
for Class I, Div 2 hazardous locations. To maintain a NEMA
4X rating, use watertight fi ttings that are rated NEMA 4X or
better.