6.

Angle card and position card holes between the holding
clips.

7.

Push card in, between holding clips. Lower card back
into position and attach card with screws and washers.

8.

Attach the chamber cover.

AMPLIFIER CONTROLS, CONTROL METHODS and DATA
DISPLAY PROGRAMMING
The M-3000 amplifi er display/programming chamber
contains a display/control card. This card and its display
screen provide easy access to meter information and the
ability to view, program and adjust meter data parameters.

Card Display and Controls
The M-3000 uses a 2.5 X 1 inch (63 X 25mm) four line, 16-
character, backlit, LCD display.

Display screens and screen data are manipulated with
magnet switches or push buttons. By operating the switches
or buttons different screens are accessed, program
parameters are selected and changed and settings are
reprogrammed.

If no contact is made with switches or buttons for 2 minutes,
in any parameter, the display returns automatically to the
Main Screen.

ACCESS to AMPIFIER SCREENS, DATA and
PARAMETER PROGRAMMING
NOTE
: The M-3000 can be programmed to meter many
fl ow situations and serve a variety of purposes during a
production process. To meet diverse needs there are a
wide variety of programming options and parameters. Your
metering requirements probably do not require the use of all
program screens, options and parameters.