M2000, Opening the cover, Connecting the cable harness – Badger Meter M-Series Field Verification Device User Manual

Page 8: Opening the cover connecting the cable harness

Advertising
background image

Page 8

8-11

Field Verification Device

M2000

Disconnect the power to the amplifier before connecting the cable harness of the Verification Device.

Opening the Cover

1. Using a ¼ inch slotted screwdriver, remove the two right-hand screws from the front of the amplifier.
2. Loosen the two left-hand screws until the screw heads protrude above the surface of the amplifier door.
3. Open the amplifier door from right side to left.

Connecting the Cable Harness

The individual connector wires are labeled as to where each connector is to be connected onto the internal circuit board of

the amplifier. A connection instruction label has been placed inside the amplifier for reference.

On the M2000 cable harness, the following connectors are tagged:

Out A B RS232 (7-pin connector)

Output C D Input (7-pin connector)

Current Loop (2-pin connector)

Detector Electrode (6=pin connector)

Detector Coil (3-pin connector)

Amplifier Electrodes (6-pin connector)

Amplifier Coil (3 Pins)

Detector Ground (alligator clip)

Figure 4: M2000 Wire Harness Connectors

Note: Refer to

"M2000 Wire Harness Circuit Board Connectors" on page 9

for the designated circuit board

connections.