M2000 harness connections – Badger Meter M-Series Field Verification Device User Manual

Page 9

Advertising
background image

Page 9

8-11

User Guide

M2000 Harness Connections

1. Clip the alligator clip labeled Detector Ground to either of the hex nuts mounted on top of the meter flanges.
2. Plug the connector labeled Amplifier Electrode into the circuit board connector labeled E1, ES, E2, RS, EP, ES.
3. Plug the Amplifier Coil Output into the circuit board connector labeled CS, C2, C1.
4. Plug the Output 1 & 2/ RS232 into the board output connector labeled 1 to 7.
5. Plug the Output 3 & 4 / Input into the board output connector labeled 1 to 14.
6. Plug the Analog Output connector into the board connector labeled 15 and 16 in connector row of

COMMUNICATION / Analog Out on the right side.

7. Connect the harness wire connector labeled Detector Electrode to the 6-wire connector from the detector.
8. Connect the harness wire connector labeled Detector Coil to the 3-wire connector from the detector.

BA

20

00-

22

M

ID

L

N

PE

JP1

JP2

COMMUNICATION

DISPLAY

CS C2 C1

E1

ES

E2

RS

EP

ES

15 16

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Output 1 & 2 / RS232

Output 3 & 4 / Input

Analog Output

Amplifier Coil

Amplifier Electrode

Figure 5: M2000 Wire Harness Circuit Board Connectors

Detector Electrode

Detector Coil

Detector Ground

Figure 6: M2000 Detector Connections