MPM, APM, PPM, & LTI Series Modbus

®

Register Tables

Serial Communication

Page 34

Table 3.

User Programmable Settings

Digital Inputs & Function Keys Setting (40152 – 40162)

Digital Outputs Settings (40163 – 40169)

Integer

Function

Key, DI

Reg. No.

Integer

Function

0 Disable

Function

F1

152

0

Disable

Function

1 Menu

Key F2

153

1

Alarms

Acknowledged

2 Right Arrow Key

F3

154

2

End of Batch

3 Up Arrow Key DI-1

155

3

Batch

Counter

Reset

4 Enter

Key DI-2

156

4

Total

Reset

5 Acknowledge Alarms

DI-3

157

5

Grand Total Reset

6

Select Reset Menu

DI-4

158

6

Maximum Value Reset

7

Select Reset Batch Counter

DI-5

159

7

Minimum Value Reset

8

Select Reset Total

DI-6

160

8

Maximum/Minimum Value Reset

9

Select Reset Grand Total

DI-7

161

9

Reserved

10

Select Reset Maximum Value

DI-8

162

10

Reserved

11

Select Reset Minimum Value

11

Alarm 1 Active

12

Select Reset Max & Min Values

12

Alarm 2 Active

13 Reserved

13

Alarm 3 Active

14 Reserved

14

Alarm 4 Active

15 Select

Relay Menu

15

Alarm 5 Active

16

Select Set Point 1 Programming

16

Alarm 6 Active

17

Select Set Point 2 Programming

17

Alarm 7 Active

18

Select Set Point 3 Programming

18

Alarm 8 Active

19

Select Set Point 4 Programming

19

Start Batch

Selected

20

Select Set Point 5 Programming

20

Stop Batch

Selected

21

Select Set Point 6 Programming

22

Select Set Point 7 Programming

DO

Reg. No.

23

Select Set Point 8 Programming

DO-1

163

24 Select

Start Batch

DO-2

164

25 Select

Stop Batch

DO-3

165

26 Reserved

DO-4

166

27 Select

Relay

Disable

DO-5

167

28 Select

Relay

Enable

DO-6

168

29 Select

Relay

Output Hold

DO-7

169

30 Reserved

DO-8

170

31 Select

Display Menu

32 Select

Big Display Menu

33

Select Maximum Value on Big Display

34

Select Minimum Value on Big Display

35

Select Maximum/Minimum Value on Big Display

36

Select Little Display Menu

37

Select Maximum Value on Little Display

Note: Some of the functions listed are dependent on

model being used. For example: the batch
functions are only available with the batch
controller model.

38

Select Minimum Value on Little Display

39

Select Maximum/Minimum Value on Little Display

40 Force

ON

Relay #1 (Relay 1 Action must be set to Off)

41 Force

ON

Relay #2 (Relay 2 Action must be set to Off)

42 Force

ON

Relay #3 (Relay 3 Action must be set to Off)

43 Force

ON

Relay #4 (Relay 4 Action must be set to Off)

44

Select Grand Total Value on Little Display (Batch)

45

Select Batch Count Value on Little Display (Batch)