MPM, APM, PPM, & LTI Series Modbus

®

Register Tables

Serial Communication

LIMModbus2DW_A.doc

10/10

Table 6.

Input Identification Configuration (49901 – 49904)

Firmware Identifier

Main Board Configuration

Input Board Configuration

Byte Product

Byte

Function

Byte

Function

039

MPM, APM, PPM

000

Process / Temp

00

Reserved

063 LTI

100

Process Totalizer

200

Pulse Totalizer

Note: Each register holds two ASCII

characters.

Example: APM (SFT039)
49901: 0x3033 = 03
49902: 0x3930 = 91
49903: 0x3030 = 00
49904: 0x3030 = 00

300

Dual Process

400

Reserved

500

Process Batching

600

Pulse Batching

700

Reserved


Table 7.

Allowable ASCII Character Set (40076 – 81, 40082 – 87,

40119 – 124)

Display

HEX ASCII

Display

HEX ASCII

Display

HEX ASCII

Display

HEX ASCII

0

30 0

A

41 A

j

4A J

v

56 V

1

31 1

b

62 b

k

4B K

u w

77 w

2

32 2

C

43 C

l

4C L

x

58 X

3

33 3

c

63 c

n m

6D m

y

59 Y

4

34 4

d

64 d

n

6E n

z

5A Z

5

35 5

e

45 E

O

4F O

-

2D -

6

36 6

f

46 F

o

6F o

/

2F /

7

37 7

g

47 G

p

50 P

[

5B ]

8

38 8

9

67 g

q

71 q

]

5D [

9

39 9

H

48 H

r

72 r

=

3D =

h

68 h

s

53 S

20 SP

I

49 I

t

74 t

!

3C <

i

69 i

u

75 u

Advertising
This manual is related to the following products:

MPM, APM