Configuring for Management

Page 2-9

address when it is connected to the network and is powered
on, if your network contains a BootP server configured with
available, valid IP addresses.

Important! BootP configuration only works if
the IntraSwitch does not have an IP address
assigned to it.

1

Make sure your network has a BootP server con-
figured with a valid IP address entry for the
IntraSwitch.

2

When the IntraSwitch is connected to the net-
work and is powered on, it automatically trans-
mits a BootP request across the network (up to
10 times) until it receives a valid IP address from
the BootP server.

3

After an IP address is received, the IntraSwitch
can be managed via in-band access. See Chapter
4 for more information.

To verify that a valid IP address was received, use a tool such as
Ping

1

to try and access the IntraSwitch; if you can access the

IntraSwitch, it is properly configured with an IP address.

See “Bootstrap Configuration” in Chapter 5 for more
information on using BootP.

Console

Configuration

To manually configure the IntraSwitch with an IP address via its
Console port, use a VT100 terminal or emulator (such as Hyper
Terminal, ProComm, or ZTerm) running on a workstation or
personal computer to connect to the switch’s Local Manage-
ment Interface.

1. Ping is an application that can be used to test whether a remote device is

properly connected to a network.

6216M Book Page 9 Wednesday, January 27, 1999 5:26 PM