Table 5-7, Snmp configuration menu settings -18, See figure 5-7 – Asante Technologies 6200 User Manual

Page 65: Table 5-7 e

Advertising
background image

Console Management

Page 5-18

Table 5-7

SNMP Configuration Menu Settings

Changing Community Strings

To change the IntraSwitch’s community strings:

1

Open the SNMP Configuration Menu by typ-
ing

n in the Configuration Menu.

2

Type

r to change the read community string

or

w to change the write community string.

3

Type a new community string at the prompt.

See Table 5-7 for a description of read and
write community strings.

To cancel a selected option, press

ctrl-c

at

the command prompt.

4

Press

Return

.

To quit and return to the Configuration
Menu, type

q.

Setting

Description

SNMP Read
Community

The IntraSwitch’s SNMP read community string.

Note: The read community string is a single word that
defines access rights for reading SNMP data objects.

The default setting is public.

SNMP Write
Community

The IntraSwitch’s SNMP write community string.

Note: The write community string is a single word that
defines access rights for writing SNMP data objects.

The default setting is private.

Trap
Authentication

The status of the SNMP agent to generate authentication
traps.

The default setting is disabled.

SNMP Trap
Receivers

The IP addresses of the network management stations
that can receive traps from the IntraSwitch.

Normally, these addresses are the same as your network
management software systems’ IP address(es).
Important! A maximum of four trap receivers is
allowed.

6216M Book Page 18 Wednesday, January 27, 1999 5:26 PM

Advertising