Figure 2-3, Local management interface main menu -10 – Asante Technologies 6200 User Manual

Page 35

Advertising
background image

Installation

Page 2-10

1

Using a

straight-through

RS-232 cable with a 9-

pin male D-subminiature plug at one end, con-
nect a terminal or workstation (PC or Macintosh)
running a terminal emulator to the

Console

port

on the front of the IntraSwitch.

2

Make sure both units are powered on.

If using a PC with a terminal emulator, make
sure it is configured with the following terminal
settings:

❏ Baud: 9600

❏ Data Bits: 8

❏ Parity: None

❏ Stop Bits: 1

❏ Flow Control: None

3

Once connected, the Local Management Main
Menu appears on the terminal screen, as shown
in Figure 2-3.

Figure 2-3

Local Management Interface Main Menu

4

Type

c to open the Configuration Menu.

The “Enter Password” prompt appears.

5

Type your password at the prompt.

Important! The default password is
Asante

. The password is case-sensitive.

6216M Book Page 10 Wednesday, January 27, 1999 5:26 PM

Advertising