NORD Drivesystems BU0240 User Manual

Page 17

Advertising
background image

2 Assembly and installation

BU 0240 GB

17

Control terminal functions

LABELLING, FUNCTION

SH:

"Safe stop" function

AS:

Integrated AS interface

24V:

External 24V power supply

GND:

Reference potential for digital signals

DIN:

Digital input

DO: Digital

output

24V SH: "Safe stop" input
GND SH: "Safe stop" reference potential
SYS+/-: System bus
MB+/-:

Electromagnetic brake control
(105V, 180V, 205V)

TF+/-:

Motor PTC connection


CONNECTIONS AND FUNCTIONS FOR SK 200E VERSIONS

FI type

Pin

Labelling

SK 205E

SK 215E (SH)

SK 225E (AS1)

SK 235E (SH + AS1)

1

44

24V, external 24V FI supply*

2

44/84

24V, external 24V FI supply

AS+, AS- Interface

3

40

GND, reference potential for digital signals

4

40/85

GND AS-

Interface

5

21

DIN1 / digital input 1

6

22

DIN2 / digital input 2

7

23

DIN3, digital input 3

8

24/89

DIN4,

digital input 4

24V SH,

“Safe stop”

DIN4,

digital input 4

24V SH,

“Safe stop”

9

40/88

GND GND

SH GND GND

SH

10

1

DO 1, digital output 1

11

40

GND

12

77

SYS+, system bus

13

78

SYS-, system bus

14

-

---

15

79

MB+, electromagnetic brake control

16

80

MB-, electromagnetic brake control

17

38

TF+, motor PTC connection

18

39

TF-, motor PTC connection

*With the use of the AS interface, terminal 44 provides an output voltage (24V, max. 60mA). In this case, no voltage

sources may be connected to this terminal!

Advertising