4 Commissioning

BU 0240 GB

21

   

 

SK 200E, internal view 

 

Plug‐in 

EEPROM

 

 

8

‐pin

 DIP

 swit

ch

 

4.1.2.2

DIP switch configuration

The DIP switches provide the possibility of carrying out commissioning without additional control units.
Additional settings are made using the potentiometer on the top of the frequency inverter.
As supplied, all DIP switches are at the “Off” position, which corresponds to control via the digital inputs.
The frequency setpoint value is adjusted via P1 and P2.

























NOTE

FACTORY SETTING, AS DELIVERED!

*) As delivered, all DIP switches are in the “off” position. Control is by means of the digital
control signals (P420 [01]-[04]) and the potentiometers P1 and P2 integrated in the FI (P400
[01]-[02]).

NOTE

For controlling the frequency inverter via In/Out bits (e.g.: AS-i, DIG In 1 - 4) typical values are
preset in the relevant parameters (P480) and (P481). (Details: Section 5)

These settings apply to both control via AS-i bits and BUS I/O bits.

No.

Bit

DIP

switches

off Behaviour corresponding to P555, P556, P557

8

2

7

Int R

Brake

Internal brake
resistor

on

Behaviour corresponding to the brake resistor
used

off

Motor data corresponding to the rated power of
the FI in kW relative to 50Hz, fmax = 50Hz

7

2

6

60Hz*

50/60Hz-operation

on

Motor data corresponding to the rated power of
the FI in hp relative to 60Hz, fmax = 60Hz

off VFC regulation corresponding to P211/P212

6

2

5

V/F

Regulating
process

on V/f curve ((

⇒ P211=0 und P212=0)

off off

Corresponding to P420 [1-4] and P400 [1-2]
or P480 [1-4] und P481 [1-4]

off on

on off

5/4

2

4/3

I/O

Potentiometer
function, digital
inputs and AS
interface

on on

Further details in the next table.
(depends on the DIP3 "BUS")

off Corresponding to P509 and P510 [1] [2]

3

2

2

BUS

Source control
word and setpoint
value

on System bus (

⇒ P509=3 and P510=3)

off off

Corresponding to P514 and 515 [32,
250kBaud]

off on Address 34, 250kBaud

on off Address 36, 250kBaud

2/1

2

1/0

ADR

System bus
address/ baud rate

on on Address 38, 250kBaud

*) A changed setting is applied the next time the mains is switched on.
Existing settings in parameters P201-P209 and P105 are overwritten!