NORD Drivesystems BU0240 User Manual

Page 23

Advertising
background image

4 Commissioning

BU 0240 GB

23

Details of potentiometers P1 and P2

The setpoint can be adjusted to a fixed value with the integrated potentiometer P1. Adjustment of the start-
up and braking ramps can be made via potentiometer P2.

Potentiometer

P1

(continuous)

P2

(stepped)

0% P102/103 P105

-

-

-

10% 0.2s

10Hz

1

P102/103 P104

20% 0.3s

20Hz

2 0.2s 2Hz

30% 0.5s

30Hz

3 0.3s 5Hz

40% 0.7s

40Hz

4 0.5s 10Hz

50% 1.0s

50Hz

5 0.7s 15Hz

60% 2.0s

60Hz

6 1.0s 20Hz

70% 3.0s

70Hz

7 2.0s 25Hz

80% 5.0s

80Hz

8 3.0s 30Hz

90% 7.0s

90Hz

9 5.0s 35Hz

100% 10.0s

100Hz

10 7.0s 40Hz

The function of P1 and P2 depends on DIP 4/5. The meaning
changes according to the setting.

As standard, P1 sets the setpoint value of 0-100% and P2 sets the
ramp from 0.2-7sec.


Potentiometer

P2

P1

Advertising