NORD Drivesystems BU0240 User Manual

Page 36

Advertising
background image

NORDAC SK 200E Manual

36

BU

0240

GB

Diagnostic LEDs

LED

Signal

Name

Colour

Description

Status

Meaning

DOUT 1

yellow

Digital output 1

on

High signal applied

DIN 1

yellow

Digital input 1

on

High signal applied

DIN 2

yellow

Digital input 2

on

High signal applied

DIN 3

yellow

Digital input 3

on

High signal applied

DIN 4

yellow

Digital input 4

on

High signal applied

TEMP

yellow

Motor PTC

on

Motor overtemperature

Chop

yellow

Brake chopper

on

Brake chopper active, brightness →

degree of load

Brake

yellow

Mech. brake

on

Mech. Brake released

BUS-S

green

System bus status

off

No process data communication

Flashing
(4 Hz)

"BUS Warning"

on

Process data communication active

⇒ Reception of at least 1 telegram / s

⇒ SDO transfer is not indicated

BUS-E

green

System bus error

off

No error

Flashing
(4 Hz)

Monitoring error P120 or P513

⇒ E10.0 / E10.9

Flashing
(1 Hz)

Error in an external system bus module

⇒ Bus module Æ Timeout on the external BUS (E10.2)

⇒System bus module has a module error (E10.3)

on

System bus in state “BUS off”

Status LEDs

LED

Signal

Name

Colour

Description

Status

Meaning

DS

dual
red/green

Frequency
inverter status

off

FI not on standby,

no mains and control voltage

green

on

FI on standby

green
flashing

0.5 Hz

FI is ready for switch-on

2

Hz

FI is in switch-on block

red/green

0.5 Hz

Warning

alternating

1 … 25Hz

Degree of overload of switched-on FI

green on +
red flashing

FI not on standby,

Control voltage available but no mains

voltage

red

flashing

Error, flashing frequency →

Error number

AS-I

dual

AS-i status

off

No voltage to the AS-i module (PWR)

red/green

green

Normal

operation

red

No exchange of data

Slave Address = 0 / Slave not in LPS /

Slave with incorrect IO/ID /
Master in STOP mode / Reset active

alternately
flashing
red / green

Peripheral

error