Adaptec SATA AND SCSI RAID CONTROLLERS User Manual

Page 34

Advertising
background image

2-6

Installing the Controller and Drives

9

Press Y, then Enter.

The selected drives are initialized, then the ACU screen is
displayed.

10

Using the arrow keys, highlight Create Array, then press Enter.

11

Using the arrow keys as in

Step 7

, highlight at least three drives to

be used in the array and press Insert for each highlighted drive.

12

Press Enter.

13

On the next screen, respond as follows:

A Creating Array window appears.

14

Press Enter to continue with the array configuration.

Note:

You can start using the array immediately. However,

performance is reduced until the build process is complete.

15

Press Esc until the Exit Utility window appears.

16

Highlight Yes, then press Enter.

The system restarts.

17

Install the driver as described in

Chapter 3

.

Property Line Displayed

Entry or Selection

Array Type

Select RAID 5, then press Enter

Array Label

Type a name, then press Enter.

Array Size

Press Enter, then press Enter again to
use the default granularity of GB.

Stripe Size

Press Enter.

Read Caching

Press Enter.

Write Caching

Press Enter.

Create RAID via

Press Enter.

[Done]

Press Enter.