ACU for DOS

HotspareDrives Keyword

HotspareDrives

is an optional keyword, specifying the hotspares

to assign to the array. The syntax for listing hotspares is the same as
the

Drives Keyword on page B-7

. If HotspareDrives is not specified,

no hotspares are assigned to the array.

Notes:

HotspareDrives

creates only dedicated hotspares. If the

same drive is assigned to protect multiple arrays, only the
last array that drive is assigned to is protected.

HotspareDrives

does not verify that the available space

on the specified hotspares is sufficient to serve as failover
for the array.

When assigning hotspares to a multilevel array,
HotspareDrives

assigns all the hotspares in the list to all

arrays within the multilevel array.

Example

HotspareDrives=0:0:0,0:1:0

InitializeAll Keyword

If you want the ACU to initialize all drives connected to the
controller and delete any existing arrays before any new arrays are
created, even those that are not specified in any Drives keyword
definition, specify InitializeAll=yes. Otherwise, the ACU
initializes only those drives specified by the Drives keyword.

Caution:

Initializing a drive automatically deletes any existing

arrays with that drive as their member.

!