Error Recovery Procedures and Fault Symptom
Codes

N1524A ACL Installation and User’s Guide for the NonStop S-Series Tape Enclosure 527340-001

C- 6

Control Error Codes

2013

Ctl. Firmware Error

A, B, 1

2014

Ctl. Firmware Error

A, B, 1

2015

Ctl. Firmware Error

A, B, 1

2016

Ctl. Firmware Error

A, B, 1

2030

LTO Timeout Error

During powerup, communication with one of the
LTO drives was unsuccessful.

A, B, 3, 1

2031

LTO Timeout Error

While trying to update the front panel,
communication with one of the LTO drives was
unsuccessful.

A, B, 3, 1

2032

LTO Timeout Error

Communication with LTO drive 1 was
unsuccessful (sequential mode)

A, B, 3, 1

2033

LTO Timeout Error

Communication with LTO drive 2 was
unsuccessful (sequential mode)

A, B, 3, 1

2034

LTO Timeout Error

While attempting to update the cartridge map,
communication with one of the LTO drives was
unsuccessful.

A, B, 3, 1

204x

Invalid Ctl Msg

An illegal message type code was received. This
can be the result of receiving a NULL type code, a
status code without a command being active, or a
command code while a command is currently
active.

A, B, 1

205x

No Free Queues

The system could not allocate a free queue

A, B, 1

206x

Calib. Error Port x

When trying to locate the unit attached to port x,
the pass-thru elevator reached the top of rail.

A, B, 4, 1

206f

Pass-thru Init Error

The pass-thru elevator did not travel a minimum
distance to reach the top of its travel.

A, B, 4, 1

2070

Command Timeout

Enter to reboot. The ten minute timer was
exceeded when trying to fetch from a drive.

A, 3, 2, 1

2071

Command Timeout

Internal error only. Not reported to the operator or
host.

D, 1

2072

Command Timeout

Power Down, Wait 30 seconds, Power Up.
Occurs if the power is cycled too quickly and the
LTO drive comes up in an error state and doesn't
communicate with the library controller. Also
occurs if a drive is removed from a dual drive
library and the unit is not re-configured (using the
ESC button).

B, 3, 1