Controlling the internal scsi bus, Controlling the external scsi bus – HP Array Controller HSG V8.7 Software User Manual

Page 106

Advertising
background image

Single-Ended I/O Module

5–4 UltraSCSI RAID Enclosure

Controlling the Internal SCSI Bus

The I/O module controls the internal SCSI bus in the following
manner:

Isolates the internal SCSI bus from the external SCSI bus

Provides single-ended SCSI bus termination for each internal bus

Disconnects the internal SCSI bus from the external SCSI bus
when directed by the EMU

Distributes TERMPOWER (+5 V dc) to the internal SCSI bus

Turns O

N

the green internal TERMPOWER LED when internal

TERMPOWER is present

Turns O

FF

the green internal TERMPOWER LED when there is

either an internal TERMPOWER overcurrent condition or no
TERMPOWER

Controlling the External SCSI Bus

The I/O module controls the external SCSI bus in the following
manner:

Provides single-ended SCSI bus termination for the external bus

Distributes TERMPOWER (+5 V dc) to the external SCSI bus

Turns O

N

the green external TERMPOWER LED when external

TERMPOWER is present

Turns O

FF

the green external TERMPOWER LED when there is

either an external TERMPOWER overcurrent condition or no
TERMPOWER

Disables the external bus termination when a cable is connected
to the right VHDCI connector

Advertising